FreeStyle Optium Neo H

Blood Glucose and Ketone Monitoring System

Accuracy, safety and compliance – all within easy reach.

Designed for easy bedside testing

  • High-contrast screen with large numbers is easy to see, easy to read
  • Fast, 5-second blood glucose test time
  • Easy, accurate blood ketone testing enables detection of elevated ketones

For professional use only.

Blood Glucose and Ketone Monitoring System FreeStyle Optium Neo H.
Blood Glucose and Ketone Monitoring System FreeStyle Optium Neo H.
Blood Glucose and Ketone Monitoring System FreeStyle Optium Neo H.

Accuracy for a broad range of patients

Overall clinical accuracy system results for glucose concentration ≥5.6 mmol/L

99.1% of results within ± 0.83 mmol/L or ± 15% of the laboratory reference, meeting ISO 15197:2013 accuracy criteria1

Wide haematocrit range with blood glucose test strips

15%-65%

Blood sample types with blood glucose test strips

Capillary, arterial, venous and neonatal whole blood

Compliance

Quality Control Reminder to encourage adherence to hospital protocols

Frequency of the reminder can be customised to each hospital or ward.

96% of hospital nurses agreed that the Quality Control Reminder would help them comply with their hospital’s protocol.2,3

Freestyle Optium Neo H quality control

Safety

 

Out-of-Range indicators support prompt action on critical blood glucose levels

Low and high indicator levels can be customised to the action ranges of your hospital.

98% of hospital nurses agreed that they would take action when seeing an out-of-range result and a lit indicator.2,3

Freestyle Optium Neo H out of range
Individually foil-
wrapped test strips

Individually foil-wrapped Blood Glucose and Ketone Test Strips to help safeguard the integrity of the testing process.

test strips

FreeStyle Auto-Assist Neo Software

 

Discover our easy-to-use software

The FreeStyle Auto-Assist Neo software is designed to help Healthcare Professionals get the most out of the FreeStyle Optium Neo H blood glucose and ketone monitoring system.  Healthcare Professionals can view and print reports, as well as configure the settings for the meter.

FreeStyle Optium Neo Blood glucose meter and LibreView report shown on a computer monitor.

References & Disclaimers

Images are for illustrative purposes only. Not real patient data.

1. According to ISO 15197:2013 accuracy criteria, 95% of the measured glucose values shall fall within either ±0.83 (±15 mg/dL) of the average measured values of the reference measurement procedure at glucose concentrations <5.55 mmol/L (<100 mg/dL) or within ±15% at glucose concentrations ≥5.55 mmol/L (≥100 mg/dL).

2. This study was conducted online in 2013 among 107 nurses in the UK and Ireland who personally conduct or supervise bedside blood glucose testing and use stand-alone blood glucose meters 50% of the time or more.

3. Data on file, Abbott Diabetes Care Inc.